Abstract

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

View on arXivView PDF

Code Implementations(1)

Full-dose Whole-body PET Synthesis from Low-dose PET using Consistency Model

140Python, Jupyter NotebookFeb 14, 20242 years ago
consistency-modelddpm

Similar Papers

Cite this paper

@article{pan2023fulldose,
  title  = {Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model},
  author = {Shaoyan Pan and Elham Abouei and Junbo Peng and Joshua Qian and Jacob F Wynne and Tonghe Wang and Chih-Wei Chang and Justin Roper and Jonathon A Nye and Hui Mao and Xiaofeng Yang},
  year   = {2023},
  eprint = {2308.13072},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2308.13072v3}
}