An end-to-end deep learning pipeline to derive blood input with partial volume corrections for automated parametric brain PET mapping

Rugved Chavan, Gabriel Hyman, Zoraiz Qureshi, Nivetha Jayakumar, William Terrell +8 more
2/5/2024
eess.IVcs.CVcs.LG

No confident code implementation found for this paper.

Abstract

Dynamic 2-[18F] fluoro-2-deoxy-D-glucose positron emission tomography (dFDG-PET) for human brain imaging has considerable clinical potential, yet its utilization remains limited. A key challenge in the quantitative analysis of dFDG-PET is characterizing a patient-specific blood input function, traditionally reliant on invasive arterial blood sampling. This research introduces a novel approach employing non-invasive deep learning model-based computations from the internal carotid arteries (ICA) with partial volume (PV) corrections, thereby eliminating the need for invasive arterial sampling. We present an end-to-end pipeline incorporating a 3D U-Net based ICA-net for ICA segmentation, alongside a Recurrent Neural Network (RNN) based MCIF-net for the derivation of a model-corrected blood input function (MCIF) with PV corrections. The developed 3D U-Net and RNN was trained and validated using a 5-fold cross-validation approach on 50 human brain FDG PET datasets. The ICA-net achieved an average Dice score of 82.18% and an Intersection over Union of 68.54% across all tested scans. Furthermore, the MCIF-net exhibited a minimal root mean squared error of 0.0052. The application of this pipeline to ground truth data for dFDG-PET brain scans resulted in the precise localization of seizure onset regions, which contributed to a successful clinical outcome, with the patient achieving a seizure-free state after treatment. These results underscore the efficacy of the ICA-net and MCIF-net deep learning pipeline in learning the ICA structure's distribution and automating MCIF computation with PV corrections. This advancement marks a significant leap in non-invasive neuroimaging.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{chavan2024endtoend,
  title  = {An end-to-end deep learning pipeline to derive blood input with partial volume corrections for automated parametric brain PET mapping},
  author = {Rugved Chavan and Gabriel Hyman and Zoraiz Qureshi and Nivetha Jayakumar and William Terrell and Stuart Berr and David Schiff and Megan Wardius and Nathan Fountain and Thomas Muttikkal and Mark Quigg and Miaomiao Zhang and Bijoy Kundu},
  year   = {2024},
  eprint = {2402.03414},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2402.03414v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2402.03414.svg)](https://codeofpaper.com/paper/2402.03414)

Discussion