PFCM: Poisson flow consistency models for low-dose CT image denoising

Dennis Hein, Grant Stevens, Adam Wang, Ge Wang
2/13/2024
eess.IVcs.CV

No confident code implementation found for this paper. 3 possible matches can be shown below.

Abstract

X-ray computed tomography (CT) is widely used for medical diagnosis and treatment planning; however, concerns about ionizing radiation exposure drive efforts to optimize image quality at lower doses. This study introduces Poisson Flow Consistency Models (PFCM), a novel family of deep generative models that combines the robustness of PFGM++ with the efficient single-step sampling of consistency models. PFCM are derived by generalizing consistency distillation to PFGM++ through a change-of-variables and an updated noise distribution. As a distilled version of PFGM++, PFCM inherit the ability to trade off robustness for rigidity via the hyperparameter $D \in (0,\infty)$. A fact that we exploit to adapt this novel generative model for the task of low-dose CT image denoising, via a ``task-specific'' sampler that ``hijacks'' the generative process by replacing an intermediate state with the low-dose CT image. While this ``hijacking'' introduces a severe mismatch -- the noise characteristics of low-dose CT images are different from that of intermediate states in the Poisson flow process -- we show that the inherent robustness of PFCM at small $D$ effectively mitigates this issue. The resulting sampler achieves excellent performance in terms of LPIPS, SSIM, and PSNR on the Mayo low-dose CT dataset. By contrast, an analogous sampler based on standard consistency models is found to be significantly less robust under the same conditions, highlighting the importance of a tunable $D$ afforded by our novel framework. To highlight generalizability, we show effective denoising of clinical images from a prototype photon-counting system reconstructed using a sharper kernel and at a range of energy levels.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. 3 weaker matches are hidden by default — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{hein2024pfcm,
  title  = {PFCM: Poisson flow consistency models for low-dose CT image denoising},
  author = {Dennis Hein and Grant Stevens and Adam Wang and Ge Wang},
  year   = {2024},
  eprint = {2402.08159},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2402.08159v2}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2402.08159.svg)](https://codeofpaper.com/paper/2402.08159)

Discussion