Abstract

Volume Interpolated Breath-Hold Examination (VIBE) MRI generates images suitable for water and fat signal composition estimation. While the two-point VIBE provides water-fat-separated images, the six-point VIBE allows estimation of the effective transversal relaxation rate R2* and the proton density fat fraction (PDFF), which are imaging markers for health and disease. Ambiguity during signal reconstruction can lead to water-fat swaps. This shortcoming challenges the application of VIBE-MRI for automated PDFF analyses of large-scale clinical data and of population studies. This study develops an automated pipeline to detect and correct water-fat swaps in non-contrast-enhanced VIBE images. Our three-step pipeline begins with training a segmentation network to classify volumes as "fat-like" or "water-like," using synthetic water-fat swaps generated by merging fat and water volumes with Perlin noise. Next, a denoising diffusion image-to-image network predicts water volumes as signal priors for correction. Finally, we integrate this prior into a physics-constrained model to recover accurate water and fat signals. Our approach achieves a < 1% error rate in water-fat swap detection for a 6-point VIBE. Notably, swaps disproportionately affect individuals in the Underweight and Class 3 Obesity BMI categories. Our correction algorithm ensures accurate solution selection in chemical phase MRIs, enabling reliable PDFF estimation. This forms a solid technical foundation for automated large-scale population imaging analysis.

View on arXivView PDF

Code Implementations(1)

robert-graf/MAGO-SPCommunity100%
MIT
00Python, Jupyter NotebookJan 28, 20256 months agoMIT

Similar Papers

Cite this paper

@article{graf2025magosp,
  title  = {MAGO-SP: Detection and Correction of Water-Fat Swaps in Magnitude-Only VIBE MRI},
  author = {Robert Graf and Hendrik Möller and Sophie Starck and Matan Atad and Philipp Braun and Jonathan Stelter and Annette Peters and Lilian Krist and Stefan N. Willich and Henry Völzke and Robin Bülow and Klaus Berger and Tobias Pischon and Thoralf Niendorf and Johannes Paetzold and Dimitrios Karampinos and Daniel Rueckert and Jan Kirschke},
  year   = {2025},
  eprint = {2502.14659},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2502.14659v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2502.14659.svg)](https://codeofpaper.com/paper/2502.14659)

Discussion