Low Complexity Point Tracking of the Myocardium in 2D Echocardiography

Artem Chernyshov, John Nyberg, Vegard Holmstrøm, Md Abulkalam Azad, Bjørnar Grenne +4 more
3/13/2025
eess.IVcs.CV

No official code found. Best implementation: artemcher/myotracker (20 stars, last commit 2025-05-06).

Abstract

Deep learning methods for point tracking are applicable in 2D echocardiography, but do not yet take advantage of domain specifics that enable extremely fast and efficient configurations. We developed MyoTracker, a low-complexity architecture (0.3M parameters) for point tracking in echocardiography. It builds on the CoTracker2 architecture by simplifying its components and extending the temporal context to provide point predictions for the entire sequence in a single step. We applied MyoTracker to the right ventricular (RV) myocardium in RV-focused recordings and compared the results with those of CoTracker2 and EchoTracker, another specialized point tracking architecture for echocardiography. MyoTracker achieved the lowest average point trajectory error at 2.00 $\pm$ 0.53 mm. Calculating RV Free Wall Strain (RV FWS) using MyoTracker's point predictions resulted in a -0.3$\%$ bias with 95$\%$ limits of agreement from -6.1$\%$ to 5.4$\%$ compared to reference values from commercial software. This range falls within the interobserver variability reported in previous studies. The limits of agreement were wider for both CoTracker2 and EchoTracker, worse than the interobserver variability. At inference, MyoTracker used 67$\%$ less GPU memory than CoTracker2 and 84$\%$ less than EchoTracker on large sequences (100 frames). MyoTracker was 74 times faster during inference than CoTracker2 and 11 times faster than EchoTracker with our setup. Maintaining the entire sequence in the temporal context was the greatest contributor to MyoTracker's accuracy. Slight additional gains can be made by re-enabling iterative refinement, at the cost of longer processing time.

View on arXivView PDF

Code Implementations(1)

Pruned CoTracker architecture for tracking the myocardium in 2D echo images.

204PythonNov 23, 20241 years agoNOASSERTION

Similar Papers

Cite this paper

@article{chernyshov2025complexity,
  title  = {Low Complexity Point Tracking of the Myocardium in 2D Echocardiography},
  author = {Artem Chernyshov and John Nyberg and Vegard Holmstrøm and Md Abulkalam Azad and Bjørnar Grenne and Håvard Dalen and Svein Arne Aase and Lasse Lovstakken and Andreas Østvik},
  year   = {2025},
  eprint = {2503.10431},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2503.10431v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2503.10431.svg)](https://codeofpaper.com/paper/2503.10431)

Discussion