Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement

Luca Caldera, Lara Cavinato, Francesca Ieva
10/24/2025
cs.CV

No confident code implementation found for this paper.

Abstract

The variability introduced by differences in MRI scanner models, acquisition protocols, and imaging sites hinders consistent analysis and generalizability across multicenter studies. We present a novel image-based harmonization framework for 3D T1-weighted brain MRI, which disentangles anatomical content from scanner- and site-specific variations. The model incorporates a differentiable loss based on the Structural Similarity Index (SSIM) to preserve biologically meaningful features while reducing inter-site variability. This loss enables separate evaluation of image luminance, contrast, and structural components. Training and validation were performed on multiple publicly available datasets spanning diverse scanners and sites, with testing on both healthy and clinical populations. Harmonization using multiple style targets, including style-agnostic references, produced consistent and high-quality outputs. Visual comparisons, voxel intensity distributions, and SSIM-based metrics demonstrated that harmonized images achieved strong alignment across acquisition settings while maintaining anatomical fidelity. Following harmonization, structural SSIM reached 0.97, luminance SSIM ranged from 0.98 to 0.99, and Wasserstein distances between mean voxel intensity distributions decreased substantially. Downstream tasks showed substantial improvements: mean absolute error for brain age prediction decreased from 5.36 to 3.30 years, and Alzheimer's disease classification AUC increased from 0.78 to 0.85. Overall, our framework enhances cross-site image consistency, preserves anatomical fidelity, and improves downstream model performance, providing a robust and generalizable solution for large-scale multicenter neuroimaging studies.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{caldera2025scanneragnostic,
  title  = {Scanner-Agnostic MRI Harmonization via SSIM-Guided Disentanglement},
  author = {Luca Caldera and Lara Cavinato and Francesca Ieva},
  year   = {2025},
  eprint = {2510.22073},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2510.22073v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2510.22073.svg)](https://codeofpaper.com/paper/2510.22073)

Discussion