High-Resolution Magnetic Particle Imaging System Matrix Recovery Using a Vision Transformer with Residual Feature Network

Abuobaida M. Khair, Wenjing Jiang, Yousuf Babiker M. Osman, Wenjun Xia, Xiaopeng Ma
11/4/2025
physics.med-phcs.CVeess.IV

No confident code implementation found for this paper. 1 possible match can be shown below.

Abstract

This study presents a hybrid deep learning framework, the Vision Transformer with Residual Feature Network (VRF-Net), for recovering high-resolution system matrices in Magnetic Particle Imaging (MPI). MPI resolution often suffers from downsampling and coil sensitivity variations. VRF-Net addresses these challenges by combining transformer-based global attention with residual convolutional refinement, enabling recovery of both large-scale structures and fine details. To reflect realistic MPI conditions, the system matrix is degraded using a dual-stage downsampling strategy. Training employed paired-image super-resolution on the public Open MPI dataset and a simulated dataset incorporating variable coil sensitivity profiles. For system matrix recovery on the Open MPI dataset, VRF-Net achieved nRMSE = 0.403, pSNR = 39.08 dB, and SSIM = 0.835 at 2x scaling, and maintained strong performance even at challenging scale 8x (pSNR = 31.06 dB, SSIM = 0.717). For the simulated dataset, VRF-Net achieved nRMSE = 4.44, pSNR = 28.52 dB, and SSIM = 0.771 at 2x scaling, with stable performance at higher scales. On average, it reduced nRMSE by 88.2%, increased pSNR by 44.7%, and improved SSIM by 34.3% over interpolation and CNN-based methods. In image reconstruction of Open MPI phantoms, VRF-Net further reduced reconstruction error to nRMSE = 1.79 at 2x scaling, while preserving structural fidelity (pSNR = 41.58 dB, SSIM = 0.960), outperforming existing methods. These findings demonstrate that VRF-Net enables sharper, artifact-free system matrix recovery and robust image reconstruction across multiple scales, offering a promising direction for future in vivo applications.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. 1 weaker match is hidden by default — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{khair2025highresolution,
  title  = {High-Resolution Magnetic Particle Imaging System Matrix Recovery Using a Vision Transformer with Residual Feature Network},
  author = {Abuobaida M. Khair and Wenjing Jiang and Yousuf Babiker M. Osman and Wenjun Xia and Xiaopeng Ma},
  year   = {2025},
  eprint = {2511.02212},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2511.02212v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2511.02212.svg)](https://codeofpaper.com/paper/2511.02212)

Discussion