LSTM VS. Feed-Forward Autoencoders for Unsupervised Fault Detection in Hydraulic Pumps

P. Sánchez, K. Reyes, B. Radu, E. Fernández
1/16/2026
cs.LG

No confident code implementation found for this paper.

Abstract

Unplanned failures in industrial hydraulic pumps can halt production and incur substantial costs. We explore two unsupervised autoencoder (AE) schemes for early fault detection: a feed-forward model that analyses individual sensor snapshots and a Long Short-Term Memory (LSTM) model that captures short temporal windows. Both networks are trained only on healthy data drawn from a minute-level log of 52 sensor channels; evaluation uses a separate set that contains seven annotated fault intervals. Despite the absence of fault samples during training, the models achieve high reliability.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{snchez2026lstm,
  title  = {LSTM VS. Feed-Forward Autoencoders for Unsupervised Fault Detection in Hydraulic Pumps},
  author = {P. Sánchez and K. Reyes and B. Radu and E. Fernández},
  year   = {2026},