MGMAR: Metal-Guided Metal Artifact Reduction for X-ray Computed Tomography

Hyoung Suk Park, Kiwan Jeon
3/13/2026
eess.IVcs.AIcs.CV

No confident code implementation found for this paper.

Abstract

An X-ray computed tomography (CT), metal artifact reduction (MAR) remains a major challenge because metallic implants violate standard CT forward-model assumptions, producing severe streaking and shadowing artifacts that degrade diagnostic quality. We propose MGMAR, a metal-guided MAR method that explicitly leverages metal-related information throughout the reconstruction pipeline. MGMAR first generates a high-quality prior image by training a conditioned implicit neural representation (INR) using metal-unaffected projections, and then incorporates this prior into a normalized MAR (NMAR) framework for projection completion. To improve robustness under severe metal corruption, we pretrain the encoder-conditioned INR on paired metal-corrupted and artifact-free CT images, thereby embedding data-driven prior knowledge into the INR parameter space. This prior-embedded initialization reduces sensitivity to random initialization and accelerates convergence during measurement-specific refinement. The encoder takes a metal-corrupted reconstruction together with a recursively constructed metal artifact image, enabling the latent field to capture metal-dependent global artifact patterns. After projection completion using the INR prior, we further suppress residual artifacts using a metal-conditioned correction network, where the metal mask modulates intermediate features via adaptive instance normalization to target metal-dependent secondary artifacts while preserving anatomical structures. Experiments on the public AAPM-MAR benchmark demonstrate that MGMAR achieves state-of-the-art performance, attaining an average final score of 0.89 on 29 clinical test cases.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{park2026mgmar,
  title  = {MGMAR: Metal-Guided Metal Artifact Reduction for X-ray Computed Tomography},
  author = {Hyoung Suk Park and Kiwan Jeon},
  year   = {2026},
  eprint = {2603.13447},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2603.13447v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2603.13447.svg)](https://codeofpaper.com/paper/2603.13447)

Discussion