Calibrated Confidence Expression for Radiology Report Generation

David Bani-Harouni, Chantal Pellegrini, Julian Lüers, Su Hwan Kim, Markus Baalmann +4 more
3/31/2026
cs.CL

No official code found. Best implementation: ChantalMP/Conrad (1 star, last commit 2026-06-18).

Abstract

Safe deployment of Large Vision-Language Models (LVLMs) in radiology report generation requires not only accurate predictions but also clinically interpretable indicators of when outputs should be thoroughly reviewed, enabling selective radiologist verification and reducing the risk of hallucinated findings influencing clinical decisions. One intuitive approach to this is verbalized confidence, where the model explicitly states its certainty. However, current state-of-the-art language models are often overconfident, and research on calibration in multimodal settings such as radiology report generation is limited. To address this gap, we introduce ConRad (Confidence Calibration for Radiology Reports), a reinforcement learning framework for fine-tuning medical LVLMs to produce calibrated verbalized confidence estimates alongside radiology reports. We study two settings: a single report-level confidence score and a sentence-level variant assigning a confidence to each claim. Both are trained using the GRPO algorithm with reward functions based on the logarithmic scoring rule, which incentivizes truthful self-assessment by penalizing miscalibration and guarantees optimal calibration under reward maximization. Experimentally, ConRad substantially improves calibration and outperforms competing methods. In a clinical evaluation we show that ConRad's report level scores are well aligned with clinicians' judgment. By highlighting full reports or low-confidence statements for targeted review, ConRad can support safer clinical integration of AI-assistance for report generation.

View on arXivView PDF

Code Implementations(1)

ChantalMP/ConradCommunity25%

Official Code for the paper Calibrated Confidence Expression for Radiology Report Generation accepted at MICCAI 2026.

11PythonJun 18, 20264 months ago

Cite this paper

@article{baniharouni2026calibrated,
  title  = {Calibrated Confidence Expression for Radiology Report Generation},
  author = {David Bani-Harouni and Chantal Pellegrini and Julian Lüers and Su Hwan Kim and Markus Baalmann and Benedikt Wiestler and Rickmer Braren and Nassir Navab and Matthias Keicher},
  year   = {2026},
  eprint = {2603.29492},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2603.29492v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2603.29492.svg)](https://codeofpaper.com/paper/2603.29492)

Discussion