Motion-Robust Deep Reconstruction for Free-Breathing Cardiac Cine MRI

Mahmut Yurt, Kanghyun Ryu, Zhitao Li, Xucheng Zhu, Xianglun Mao +6 more
5/20/2026
eess.IVcs.LG

No confident code implementation found for this paper. 2 possible matches can be shown below.

Abstract

Conventional cardiac cine MRI relies on breath-hold Cartesian acquisitions, which are vulnerable to motion artifacts and can be uncomfortable or infeasible, particularly for pediatric and other noncompliant patients who cannot reliably hold their breath. Free-breathing radial acquisitions can alleviate these limitations, but robust reconstruction at high acceleration remains challenging due to prominent streak artifacts. To address these limitations, we propose Cine-DL, a clinically oriented framework that couples targeted k-space preprocessing with fast, model-based deep reconstruction. In this pipeline, raw free-breathing radial data undergo retrospective cardiac binning and respiratory gating to resolve cardiac phases and discard motion-corrupted spokes. We then introduce Streak Optimized Coil Compression (SOC), which explicitly preserves cardiac signals while suppressing peripheral interference that typically drives the streak artifacts. The resulting 2D+t cine series is reconstructed with an unrolled network that alternates a ResNet proximal operator with physics-based data consistency updates solved via conjugate gradient. We further employ a memory-efficient training strategy that reduces peak memory usage. We evaluate Cine-DL on free-breathing volunteer data against established baselines (k-t SENSE and iGRASP) and demonstrate clinical translation via hospital deployment on newly acquired patient data. Our experiments show that Cine-DL consistently improves quantitative metrics and visual fidelity, supporting a practical route toward routine, time-sensitive clinical adoption of free-breathing cine MRI.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. 2 weaker matches are hidden by default — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{yurt2026motionrobust,
  title  = {Motion-Robust Deep Reconstruction for Free-Breathing Cardiac Cine MRI},
  author = {Mahmut Yurt and Kanghyun Ryu and Zhitao Li and Xucheng Zhu and Xianglun Mao and Martin Janich and Marcus Alley and Kawin Setsompop and John Pauly and Shreyas Vasanawala and Ali Syed},
  year   = {2026},
  eprint = {2605.20687},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2605.20687v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2605.20687.svg)](https://codeofpaper.com/paper/2605.20687)

Discussion