Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation

Xin Ci Wong, Duygu Sarikaya, Kieran Zucker, Marc De Kamps, Nishant Ravikumar
6/17/2026
cs.CVcs.LG

No confident code implementation found for this paper.

Abstract

Glioma segmentation in multiparametric MRI is a critical component of treatment planning. A segmentation model that fails silently on treatment-critical sub-regions represents a patient safety risk that overlap-based metrics such as Dice scores cannot expose. We ask whether voxel-level uncertainty estimation via Monte Carlo (MC) Dropout can reliably identify segmentation errors in clinically critical sub-regions, and whether calibration failure modes are detectable from standard reporting metrics alone. In an empirical two-model case study on 126 BraTS21 patients, we evaluate a high-performance pretrained SegResNet and a locally trained UNet with residual units (UNet-Res). MC dropout preserved segmentation accuracy ($|Δ\text{Dice}|$ $<0.01$) while achieving strong uncertainty-error alignment (AUROC for entropy (H) $\approx$0.97), indicating uncertainty correctly ranks erroneous voxels above correct ones. Entropy-based patient stratification identified a high-uncertainty subgroup with substantially lower segmentation performance (median whole-tumour Dice $0.835$ vs. $0.925$), supporting uncertainty as a practical triage signal. However, global alignment can mask important region-specific differences. Despite similar AUROC, UNet-Res exhibited near-zero enhancing tumour entropy ($0.054$) and Expected Calibration Error (ECE) of $0.915$, with a Dice of only $0.714$, indicating severely miscalibrated confidence on the most clinically critical sub-region, a failure mode invisible to standard Dice and AUROC reporting. These findings demonstrate that strong uncertainty-error alignment is necessary but insufficient for clinical safety: sub-region-specific calibration assessment must accompany AUROC evaluation when selecting models for clinical deployment.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{wong2026confidence,
  title  = {Confidence is Not Reliability: Rethinking MC Dropout in Brain Tumour Segmentation},
  author = {Xin Ci Wong and Duygu Sarikaya and Kieran Zucker and Marc De Kamps and Nishant Ravikumar},
  year   = {2026},
  eprint = {2606.19300},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2606.19300v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2606.19300.svg)](https://codeofpaper.com/paper/2606.19300)

Discussion