Shadow Reduction in Ultrasound Imaging Using Differentiable Simulation and Radiance Field Decomposition

Valentin Bacher, Pak Hei Yeung, Bernhard Kainz, Madeleine K. Wyburd, Nicola K. Dinsdale +2 more
9/24/2026
cs.CV

No confident code implementation found for this paper.

Abstract

Acoustic shadows from bone and other highly attenuating tissues obscure clinically important structures in ultrasound. In fetal brain imaging, skull-induced artefacts disproportionately degrade the hemisphere closer to the transducer (proximal), limiting symmetric assessment of the two hemispheres. Existing correction methods require raw scanner data, impose restrictive assumptions on tissue properties, or rely on generative models that may hallucinate anatomy. We present RFlash, a physics-informed post-processing method that decomposes beamformed ultrasound images into explicit attenuation and scatter-intensity maps using a differentiable radiance-field formulation of image formation. Attenuation-adaptive re-rendering then removes the dependence of the signal at each depth on the intervening tissue, equivalent to virtually advancing the transducer into the tissue. Across 1,261 3D fetal brain volumes, 143 real 2D curvilinear abdominal scans, and 1,200 simulated 2D linear-probe liver scans, RFlash reduces shadow-related intensity differences more effectively than classical Hughes-Duck attenuation correction. For a gestational-age model trained on the distal hemisphere (further from the transducer) and applied to the proximal hemisphere, prediction error decreases by 5.1 days (40%) relative to the original images. The estimated attenuation maps also yield shadow-confidence maps that improve random-forest bone-shadow segmentation over the image alone and receive greater SHAP importance than an existing neural confidence-map baseline, suggesting greater physical consistency. RFlash requires neither hardware modification nor access to raw scanner data and supports 2D and 3D acquisitions with linear and curvilinear probes, making it widely applicable allowing clinicians to use our method on their already acquired scanners and images.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Cite this paper

@article{bacher2026shadow,
  title  = {Shadow Reduction in Ultrasound Imaging Using Differentiable Simulation and Radiance Field Decomposition},
  author = {Valentin Bacher and Pak Hei Yeung and Bernhard Kainz and Madeleine K. Wyburd and Nicola K. Dinsdale and Michael Gray and Ana I. L. Namburete},
  year   = {2026},
  eprint = {2609.29373},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2609.29373v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2609.29373.svg)](https://codeofpaper.com/paper/2609.29373)

Discussion