Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence

Yuchen Yang, Xin Wang, Lufan Wang, Yinghong Pan, Yujuan Feng +1 more
10/8/2026
cs.CVcs.AI

No confident code implementation found for this paper. 1 possible match can be shown below.

Abstract

Generating ultrasound reports from multiple images requires aggregating clinical evidence across views, yet archived key frames capture only part of the dynamic examination. Raw-report imitation is therefore misaligned with visual supervision: content that is clinically valid for the full examination may be unverifiable from the images available to a model. This gap creates a clinical behavior alignment problem. A model must preserve visible findings, avoid diagnostic reversals and unsupported completion, and not collapse into conservative templates. We propose CAMEO, a Clinically Aware Multi-image Evidence-grounded Orchestration framework for ultrasound report generation. Stage I learns ultrasound visual-language primitives; Stage II performs Cross-View Evidence Grounding by distilling trusted visible report points into multi-image QA and report-style supervision; and Stage III performs Clinically Aware Preference Alignment using clinical-error-oriented preference pairs. From USReport, we construct USReport-Distilled with 17,670 evidence-grounded paired-image training instances and USReport-Pref with 21,869 preference pairs; we additionally use 25,631 PubMedVision-US ultrasound instruction samples for domain adaptation and multi-image instruction tuning. On the primary USReport-Distilled benchmark, CAMEO improves over EchoVLM from 0.25 to 0.40 BLEU-1, 0.28 to 0.45 ROUGE-1, and 0.27 to 0.43 METEOR, while raising ClinicalScore from 55.02 to 74.20. These results underscore the value of evidence-grounded supervision, clinically aware alignment, and clinically structured evaluation for reliable ultrasound report generation.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. 1 weaker match is hidden by default — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{yang2026beyond,
  title  = {Beyond Report Imitation: Clinically Aware Multi-Image Ultrasound Report Generation from Visible Evidence},
  author = {Yuchen Yang and Xin Wang and Lufan Wang and Yinghong Pan and Yujuan Feng and Yuqing Yang},
  year   = {2026},
  eprint = {2610.11610},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2610.11610v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2610.11610.svg)](https://codeofpaper.com/paper/2610.11610)

Discussion