When PTQ Calibration Helps or Hurts: Dose-Driven Collapse and Validation-Gated Abstention in Quantized Text Embedders

Hyojung Han, Ryangkyung Kang, Youngeun Kim, Seung-Hun Jeon
10/19/2026
cs.AI

No confident code implementation found for this paper.

Abstract

Learned post-training quantization (PTQ) calibration fits quantizer parameters on a small calibration set, and for a text embedder the natural supervision is retrieval relevance. We ask two questions that are usually conflated: how far to calibrate, and whether to calibrate at all. Across three embedders (e5-base-v2, BGE-M3, EmbeddingGemma-300m) at 4-bit weight quantization, 161 calibration runs, the outcome of a fixed procedure ranges from a gain to catastrophic degradation, and the driver is the dose of the update, measured as the functional displacement D_func of the quantized model from its uncalibrated start. On EmbeddingGemma the same learning-rate grid gives +1.47 to -71.53 points of in-domain NDCG@10 change; a label-free cosine objective collapses at the same dose (-69.52 vs -71.63), so the collapse is a property of learnable calibration rather than of retrieval supervision. Objective sensitivity is heterogeneous: on e5, ranking calibration is substantially more robust than cosine at matched displacement (+14.16 +/- 4.34 pp, 95% t-CI [+3.37, +24.96], three paired slates), whereas on BGE-M3 the ordering is directionally opposite but unresolved ([-5.18, +2.38]). Dose is the main axis but not a sufficient statistic: equal D_func reached along different paths differs by up to 1.61 pp. We therefore treat calibration as an optional intervention. A pre-registered rule that accepts a checkpoint only when a per-query paired confidence interval on a 25% calibration-validation split clears the uncalibrated baseline was run on 6 independent slates and five arms. It never selected a checkpoint below its slate's baseline (0 harmful selections in 30 decisions), retained 8 of 11 beneficial updates, and paid a mean oracle regret of 1.52 pp with one abstention that forfeited 11.13 pp, a safety-opportunity trade-off, not a free improvement. We report what remains open, including label efficiency.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{han2026when,
  title  = {When PTQ Calibration Helps or Hurts: Dose-Driven Collapse and Validation-Gated Abstention in Quantized Text Embedders},
  author = {Hyojung Han and Ryangkyung Kang and Youngeun Kim and Seung-Hun Jeon},
  year   = {2026},
  eprint = {2610.27397},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2610.27397v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2610.27397.svg)](https://codeofpaper.com/paper/2610.27397)

Discussion