Automated radiotherapy treatment planning guided by GPT-4Vision

Sheng Liu, Oscar Pastor-Serrano, Yizheng Chen, Matthew Gopaulchan, Weixing Liang +8 more
6/21/2024
physics.med-phcs.AI

No confident code implementation found for this paper. 2 possible matches can be shown below.

Abstract

Objective: Radiotherapy treatment planning is a time-consuming and potentially subjective process that requires the iterative adjustment of model parameters to balance multiple conflicting objectives. Recent advancements in frontier Artificial Intelligence (AI) models offer promising avenues for addressing the challenges in planning and clinical decision-making. This study introduces GPT-RadPlan, an automated treatment planning framework that integrates radiation oncology knowledge with the reasoning capabilities of large multi-modal models, such as GPT-4Vision (GPT-4V) from OpenAI. Approach: Via in-context learning, we incorporate clinical requirements and a few (3 in our experiments) approved clinical plans with their optimization settings, enabling GPT-4V to acquire treatment planning domain knowledge. The resulting GPT-RadPlan system is integrated into our in-house inverse treatment planning system through an application programming interface (API). For a given patient, GPT-RadPlan acts as both plan evaluator and planner, first assessing dose distributions and dose-volume histograms (DVHs), and then providing textual feedback on how to improve the plan to match the physician's requirements. In this manner, GPT-RadPlan iteratively refines the plan by adjusting planning parameters, such as weights and dose objectives, based on its suggestions. Main results: The efficacy of the automated planning system is showcased across 17 prostate cancer and 13 head and neck cancer VMAT plans with prescribed doses of 70.2 Gy and 72 Gy, respectively, where we compared GPT-RadPlan results to clinical plans produced by human experts. In all cases, GPT-RadPlan either outperformed or matched the clinical plans, demonstrating superior target coverage and reducing organ-at-risk doses by 5 Gy on average (15 percent for prostate and 10-15 percent for head and neck).

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. 2 weaker matches are hidden by default — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{liu2024automated,
  title  = {Automated radiotherapy treatment planning guided by GPT-4Vision},
  author = {Sheng Liu and Oscar Pastor-Serrano and Yizheng Chen and Matthew Gopaulchan and Weixing Liang and Mark Buyyounouski and Erqi Pollom and Quynh-Thu Le and Michael Gensheimer and Peng Dong and Yong Yang and James Zou and Lei Xing},
  year   = {2024},
  eprint = {2406.15609},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2406.15609v3}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2406.15609.svg)](https://codeofpaper.com/paper/2406.15609)

Discussion