Deep Radiomics Detection of Clinically Significant Prostate Cancer on Multicenter MRI: Initial Comparison to PI-RADS Assessment

G. A. Nketiah, M. R. Sunoqrot, E. Sandsmark, S. Langørgen, K. M. Selnæs +3 more
10/21/2024
eess.IVcs.CV

No confident code implementation found for this paper.

Abstract

Objective: To develop and evaluate a deep radiomics model for clinically significant prostate cancer (csPCa, grade group >= 2) detection and compare its performance to Prostate Imaging Reporting and Data System (PI-RADS) assessment in a multicenter cohort. Materials and Methods: This retrospective study analyzed biparametric (T2W and DW) prostate MRI sequences of 615 patients (mean age, 63.1 +/- 7 years) from four datasets acquired between 2010 and 2020: PROSTATEx challenge, Prostate158 challenge, PCaMAP trial, and an in-house (NTNU/St. Olavs Hospital) dataset. With expert annotations as ground truth, a deep radiomics model was trained, including nnU-Net segmentation of the prostate gland, voxel-wise radiomic feature extraction, extreme gradient boost classification, and post-processing of tumor probability maps into csPCa detection maps. Training involved 5-fold cross-validation using the PROSTATEx (n=199), Prostate158 (n=138), and PCaMAP (n=78) datasets, and testing on the in-house (n=200) dataset. Patient- and lesion-level performance were compared to PI-RADS using area under ROC curve (AUROC [95% CI]), sensitivity, and specificity analysis. Results: On the test data, the radiologist achieved a patient-level AUROC of 0.94 [0.91-0.98] with 94% (75/80) sensitivity and 77% (92/120) specificity at PI-RADS >= 3. The deep radiomics model at a tumor probability cut-off >= 0.76 achieved 0.91 [0.86-0.95] AUROC with 90% (72/80) sensitivity and 73% (87/120) specificity, not significantly different (p = 0.068) from PI-RADS. On the lesion level, PI-RADS cut-off >= 3 had 84% (91/108) sensitivity at 0.2 (40/200) false positives per patient, while deep radiomics attained 68% (73/108) sensitivity at the same false positive rate. Conclusion: Deep radiomics machine learning model achieved comparable performance to PI-RADS assessment in csPCa detection at the patient-level but not at the lesion-level.

View on arXivView PDF

Code Implementations

No confident code match yet

We couldn't find an author-owned or strongly-evidenced community implementation for this paper. Any repos shown below are weak matches — verify before relying on them.

No code implementations found yet.

Know of an implementation? Let us know in the comments below!

Similar Papers

Cite this paper

@article{nketiah2024deep,
  title  = {Deep Radiomics Detection of Clinically Significant Prostate Cancer on Multicenter MRI: Initial Comparison to PI-RADS Assessment},
  author = {G. A. Nketiah and M. R. Sunoqrot and E. Sandsmark and S. Langørgen and K. M. Selnæs and H. Bertilsson and M. Elschot and T. F. Bathen},
  year   = {2024},
  eprint = {2410.16238},
  archivePrefix = {arXiv},
  url    = {http://arxiv.org/abs/2410.16238v1}
}

Add a badge to your README

Shows whether official code is linked for this paper.

Code of Paper badge
[![Code of Paper](https://codeofpaper.com/badge/2410.16238.svg)](https://codeofpaper.com/paper/2410.16238)

Discussion